3 Operating Sequences

3.2.3 Influencing "AUTOMATIC" operation

3.2.3
Influencing "AUTOMATIC" operation
General:
Influencing "AUTOMATIC" operation (e.g. through programmed functions), is displayed in the
first line of the CRT display.
Display:
STOP: AUTO interrupted
Interruption of "AUTOMATIC" operation (program hold),
see 3.2.3.4 "Program Interruption"
Display:
STOP: Single block
The single block has been processed
(with switch position "Single block - ON")
Display:
STOP: Pr. stop M00, M01
Programmed interruption of the program process
with "Program start"
Display:
STOP:
Read enable is a PLC output signal. When the read enable signal is
removed, the processing of the current NC block is finished. The next
program block is not transferred for processing.
Display:
STOP Dwell time
Processing of the program is interrupted for the duration of the
programmed dwell time.
Note:
"Feed hold" is not displayed on the CRT !
3-96
Read enable
© Siemens AG 1990 All Rights Reserved
the processing of the program
is continued
SINUMERIK 810M, GA3 (BN)
11.90
6ZB5 410-0EQ02