3 Operating Sequences
3.2.3 Influencing "AUTOMATIC" operation
DRY
YES-NO
Display:
All blocks in which a feedrate is programmed (G01, G02, G03, G33, G34, G35), will now be
traversed at the feedrate value entered into the "Dry run feedrate" setting data, instead of
the programmed feedrate!
The dry run feedrate then applies to "Feed per revolution" G95, and the feedrates for
threading (G33, G34, G35).
OPT. STOP
YES-NO
Display:
When an "M01" is present in the part program, the program is stopped!
When the softkey function is marked with "NO", "M01" is ignored.
OVERR.
YES-NO
Display:
This signal presupposes that there is only one common feedrate/rapid override switch. If the
softkey function is set to "NO", this override switch is only active with "feedrate".
If the softkey function is set to "YES", the override set with this overrride switch is also
effective for "rapid traverse".
3-98
You select, for example, the "DRY RUN FEEDRATE" softkey.
Dry run feedrate
You select, for example, the "OPTIONAL STOP" softkey function
Optional stop
You select, for example, the "RAPID OVERRIDE" softkey
function.
Rapid override
© Siemens AG 1990 All Rights Reserved
YES
YES
YES
6ZB5 410-0EQ02
SINUMERIK 810M, GA3 (BN)
09.91