Reset" With Change Of Operating Mode - Siemens SINUMERIK 810M Operating And Programming Manual

Hide thumbs Also See for SINUMERIK 810M:
Table of Contents

Advertisement

2 Operation

2.3.4 "Reset" with change of operating mode

2.3.4
"Reset" with change of operating mode
When changing from one selected operating mode to another (Handling see 2.3.3.1 and /
or 2.3.3.2), a " RESET" can be generated by the control.
The "RESET" generated by the control when changing has the same effect as if the
"RESET" key has been operated (see Sections 2.1.1.6 or 2.1.2.1).
The generation of a "RESET" depends on the modes switched.
MDI AUTO-
PRESET
MATIC
PRESET
MDI AUTO
-
+
MATIC
+
JOG
+
REPOS
AUTO-
+
MATIC
INC
+
...
REF-
+
POINT
Generation of "RESET" with change of operating mode
+
o
(
... Reset,
... no reset)
Examples:
1) When changing from "AUTOMATIC" to "JOG" mode, no "RESET" is generated by the
control!
2)
When changing from "JOG" to "REFPOINT" mode, a "RESET" is generated by the
control!
2-42
JOG
REPOS
+
+
+
+
+
+
o
+
o
+
o
o
+
o
o
+
+
+
© Siemens AG 1990 All Rights Reserved
AUTO-
INC
REF-
MATIC
...
POINT
+
+
+
+
+
+
o
o
+
o
o
+
o
+
o
+
+
+
6ZB5 410-0EQ02
SINUMERIK 810M, GA3 (BN)
11.90

Advertisement

Table of Contents
loading