09.91
2089
Alarm No.
Alarm Text
"Battery alarm abs. submod. 2"
Reason:
Battery voltage is too low. Battery test is performed every 10 min.
Remedy:
Replace battery module on absolute encoder module 2 while the
control is switched on.
2152
Alarm No.
Alarm Text:
"Spindle speed too high"
Reason:
The actual spindle speed is higher than that set in machine data.
– Program a smaller S value
– G92 S ... with v-constant
– Search for a block number in the "EDIT" mode
("AUTOMATIC"mode)
Remedy:
2153
Alarm No.
Alarm Text:
"Control loop spindle HW"
Reason:
As for alarm 132*
Effect:
– Inhibiting of NC START
– Operation is brought to a defined standstill
Remedy:
As for alarm 132*
2154
Alarm No.
Alarm Text:
"Spindle measuring system dirty"
Reason:
On measuring systems with a contamination signal, the measuring
system has signalled a fault to the NC
Effect:
Inhibiting of NC START
Remedy:
Check the measuring system
2155
Alarm No.
Alarm Text:
"Option M19 not available"
Reason:
"M19 S ..." has been programmed, although this function is not
present
Effect:
Inhibiting of NC START
Remedy:
– Correct program
– Retrofit option "M19"
2160
Alarm No.
Alarm Text:
"Scale factor not allowed"
Remedy:
Modify scale factor
2161
Alarm No.
Alarm Text:
"Scale change not allowed"
Remedy:
Correct scale factor modification
2171
Alarm No.
Alarm Text:
"Approach not possible"
Remedy:
Correct approach block
© Siemens AG 1990 All Rights Reserved
SINUMERIK 810M, GA3 (BN)
Check or inform Service
6ZB5 410-0EQ02
4 Monitoring Functions
4.6 Listing of the alarms/alarm description
4-21