2.1.2 Rotary Switch for Channel No. Setting

Rotary switch for setting No. of channels (3)
The device used by the PLC is determined by the setting of the rotary switch for setting the No. of
channels.
Rotary
switch No.
0
X00~X1F
1
X20~X3F
2
X40~X5F
3
X60~X7F
4
X80~X9F
5
XA0~XBF
6
XC0~XDF
7
XE0~XFF
The values shown in parentheses are the device range when mounted to the right side of the unit.
No. of channels occupied by each unit
No. of occupied channels
1
2
Several remote I/O units can be used in combination. Make sure that the total of stations possessed
by the serial link connection (MC link B) is 8 stations or less. Set a unique station No. for each unit
and make sure that these station numbers are not duplicated. There is one station No. setting rotary
switch on the DX10* unit, and two on the DX11*/12*/14* unit.
Set as shown below when connected to the communication terminal (CR05).
Rotary switch No.
0
1
2
3
2. SYSTEM CONFIGURATION
2.1 Relation of RIO Unit and Devices
Set between 0 and 7.
Device No. read in
RIO-M
RIO-M/S
X100~X11F
X120~X13F
X140~X15F
X160~X17F
X180~X19F
X1A0~X1BF
X1C0~X1DF YC0~YDF
X1E0~X1FF
DX100/DX101
DX110/DX111, DX120/DX121, DX140/DX141
Device No. read in
Output device No.
RIO-M
Y00~Y1F (Y0F)
Y100~Y11F (Y10F)
Y20~Y3F (Y2F)
Y120~Y13F (Y12F)
Y40~Y5F (Y4F)
Y140~Y15F (Y14F)
Y60~Y7F (Y6F)
Y160~Y17F (Y16F)
Y80~Y9F (Y8F)
Y180~Y19F (Y18F)
YA0~YBF (YAF)
Y1A0~Y1BF (Y1AF)
Y1C0~Y1DF
(YCF)
(Y1CF)
YE0~YFF (YEF)
Y1E0~Y1FF (Y1EF)
Unit name
R90, R91
R92, R93
R94, R95
R96, R97
2-4
Analog
output (AO)
RIO-M/S
The rotary
switches
correspond to
the file
registers
R100 to R103
in order of
small
numbers.
Output device No.
R190, R191
R192
R193, R194
R195