Communication Speed Setting

Set the communication speed of the modules.
Item
Communication Speed
*1 This communication speed can be used for the version of Add-on baseSystem "1.8" or later.
For details of the connection of a module or device in the communication speed setting, refer to "SYSTEM
CONFIGURATION" in the following manual.
MELSEC iQ-R Motion Module User's Manual (Startup)
Precautions
When the speed is set to 100 Mbps, the module can not be connected with the device station (1 Gbps) which is not
compatible with 100 Mbps.

Supplementary Cyclic Settings

Set the station-based block data assurance and I/O maintenance settings.
Item
Station-based Block Data Assurance
I/O
Output Hold/Clear
Maintenance
Setting during CPU
Settings
STOP
Data Link Error
Station Setting
Output Mode upon
CPU Error

Transient Transmission Group No. Setting

Set the transient transmission group No.
Item
Transient Transmission Group No.
Setting
*1 When the version of Add-on baseSystem is "1.22" or earlier, a Motion module error will occur when a value other than "0" is set.

Communication Mode

Set the communication mode.
Item
Communication Mode
*1 When the version of Add-on baseSystem is "1.22" or earlier, a Motion module error will occur.
Description
Select the communication speed of the modules.
Description
Set whether to assure the data by station for link fresh between the CPU module and Motion
module. Regardless of the setting, the Motion control station is operated with "Disable".
(Page 33 Direct access to link devices)
Set whether to hold or clear the output when the CPU module is changed from RUN to STOP
on the sending side. Regardless of the setting, the motion control station is operated with
"Hold". (Page 47 I/O maintenance settings)
Set whether to hold or clear the input from a disconnected station on the receiving side.
Regardless of the setting, the motion control station is operated with "Hold". (Page 47 I/O
maintenance settings)
Set whether to hold or clear the output when a stop error occurs in the CPU module on the
sending side. Regardless of the setting, the motion control station is operated with "Hold".
(Page 47 I/O maintenance settings)
Description
Set the group No. to perform transient transmission using group specification.
Description
Set the communication mode.
Setting range
• 1 Gbps
*1
• 100 Mbps
(Default: 1 Gbps)
Setting range
• Enable
• Disable
(Default: Enable)
• Hold
• Clear
(Default: Hold)
• Clear
• Hold
(Default: Clear)
• Clear
• Hold
(Default: Clear)
*1
Setting range
0 to 32 (0: No group
specification)
(Default: 0)
Setting range
• Unicast
*1
• Multicast
(Default: Unicast)
2 PARAMETER SETTINGS
2.4 Application Settings
2
109