Mitsubishi Electric MELDAS C6 Interface Manual page 248

Cnc
Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

B con-
Signal name
tact
PROGRAM DISPLAY
DURING OPERATION
[Function]
This signal is used to display a program on the Word Edit screen during operation.
[Operation]
When the "Program display during operation" signal (PDISP) turns ON, the program being operated
will appear in the program display of the EDIT screen.
B con-
Signal name
tact
OPTIONAL BLOCK SKIP
[Function]
Block accompanying "/" (slash) can be skipped.
By creating a machining program with a "/" code inserted, a different part can be machined with one
program.
[Operation]
(1) When a program having a block with "/" (slash code) placed at the head of block is executed
with "Optional block skip (BDT1)" signal turned ON, the block is skipped. The block with the "/"
code in the middle instead of at the head will be executed.
When the signal (BDT1) is OFF, block with "/" is executed.
N1G90G00Z3. M03S1000 ;
N2G00X50. ;
G01Z-20. F100 ;
G00Z3. ;
/N3G00X30. ;
/
G01Z-20. F100 ;
/
G00Z3. ;
N4G00X10. ;
G01Z-20. F100 ;
G00Z3. ;
N5G28X0Z0M05 ;
N6M02 ;
6. EXPLANATION OF INTERFACE SIGNALS
6.3 PLC Output Signals (Bit Type: Y***)
Signal
abbreviation
PDISP
Signal
abbreviation
BDT1
When the optional block skip signal (BDT1) is
on, the block with "/" will not be executed.
6-3-51
1st system
2nd system
Y72C
Y80C
1st system
2nd system
Y72D
Y80D
3rd system
Y8EC
3rd system
Y8ED

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t

Table of Contents