Classification Of Machine Input/Output Signals; Allocation Of Machine Input/Output Signals - Mitsubishi Electric MELDAS C6 Interface Manual

Cnc
Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

3.2 Classification of Machine Input/Output Signals

The signals handled by the PLC are classified as shown below.
Refer to the following table when making allocations during design.
Signal type
RIO-M
RI
RIO-M/S
EXT
DI
AI
(Analog input)
RIO-M
RO
RIO-M/S
EXT
DO
AO
(Analog
Output)
CR05

3.3 Allocation of Machine Input/Output Signals

The signals are allocated to the devices of machine input/output signals X and Y, and the device
Nos. are determined automatically depending on the connection destinations.
The connection destinations and allocated device Nos. are as below:
Destination
Input device
RIO-M
RIO-M/S
X100~X1FF
EXT1
X200~X27F
EXT2
X280~X2FF
(Note 1)
EXT3
X300~X37F
(Note 1)
EXT4
X380~X3FF
DIO
X400~X40F
(Note 2)
CR05
(Note 1) Another unit for extension is necessary to use the expansion slot 3 and 4.
(Note 2) This is connected to the communication terminal.
(Note 3) The unused I/O can be used as input/output device of each type network. Furthermore,
the input/output devices of slot with the expansion cards (Ethernet cards, etc.) which do
not need the input/output devices is also unused, and that can be used.
3. INPUT/OUTPUT SIGNALS WITH MACHINE
3.2 Classification of Machine Input/Output Signals
Allocation
table
(1) Allocated to device X.
Table 3-1-1 to
(2) Some connector pin allocations are determined.
3-1-8
1) Stroke end signal (+, -)
Table 3-2-1 to
2) Reference point return near-point detection signal
3-2-8
(3) The high-speed processing input is set with the parameters.
(Read in at the head of the high-speed processing scan.)
-
(4) The device used for EXT differs according to the network
type and specifications. Refer to section "6.6 Network related
Table 3-3
functions" for details.
(1) The connector pin allocation is determined.
Table 4-2-1
(2) Allocated to the file register (R).
Table 3-4-1 to
(1) Allocated to device Y.
3-4-8
(2) The high-speed processing output is set with the parameters.
(Output at end of the high-speed processing scan.)
Table 3-5-1 to
3-5-8
(3) The device used for EXT differs according to the network
type and specifications. Refer to section "6.6 Network related
-
functions" for details.
Table 3-6
(1) The connector pin allocation is determined.
(2) Data to be D/A converted and output can be output by
Table 4-4-1
reading it into the file register (R).
(1) This is the operation board remote I/O connection device.
(2) Allocated to the file register (R).
Table 3-7
Output device
X0~XFF
Y0~YFF
Y100~Y1FF
Y200~Y27F
Y280~Y2FF
Y300~Y37F
Y380~Y3FF
Y400~Y40F
R90~R97
R190~R195
Explanation
Points
256
Remote I/O connection
256
Remote I/O connection
128
Expansion slot 1
128
Expansion slot 2
128
Expansion slot 3 (External slot)
128
Expansion slot 4 (Not used)
16
Built-in DIO
128/96
Operation board remote I/O connection
3-2
Remarks

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t

Table of Contents