Mitsubishi Electric MELDAS C6 Interface Manual page 126

Cnc
Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

B con-
Signal name
tact
IN SYNCHRONOUS FEED
[Function]
This signal is output during execution of synchronous feed command.
[Operation]
The signal turns ON when:
(1) Synchronous feed command (G94) is given.
The signal turns OFF when:
(1) Asynchronous feed command (G95) is given.
B con-
Signal name
tact
IN CONSTANT SURFACE
SPEED
[Function]
This signal informs that automatic operation is under constant circumferential (surface) speed
control.
[Operation]
The signal turns ON when:
(1) Constant surface speed control mode (G96) is selected during automatic operation.
The signal turns OFF when:
(1) Constant surface speed control OFF command (G97) is given.
Motion
G00
command
In constant surface
speed (CSS)
(Note 1) This signal (CSS) is output even during machine lock.
6. EXPLANATION OF INTERFACE SIGNALS
6.1 PLC Input Signals (Bit Type: X***)
Signal
abbreviation
SYN
Signal
abbreviation
CSS
G96 G1 X30. S30;
G0 X- ;
1st system
X624
1st system
X625
G0Z-10.;
G97 G01· · · ·
6-1-37
2nd system
3rd system
X6A4
X724
2nd system
3rd system
X6A5
X725

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t

Table of Contents