B con-
Signal name
tact
DATA COUNT VALID
[Function]
Tool life counter becomes applicable when this signal is used during tool life control.
[Operation]
When tool life control function is available, counter (count of tool service time or cycles) becomes
valid. This signal becomes valid when "In tool life management input" (Y78B) is ON.
[Related signals]
In tool life management input (TLF1: Y78B), tool alarm 1/tool skip tool (TAL1: Y788) and tool alarm
2 (TAL2: Y789)
B con-
Signal name
tact
TOOL LIFE MANAGEMENT
INPUT (M SYSTEM)
[Function]
Tool life management function becomes valid when this signal is given.
[Operation]
When tool life management function is available, tool life can be controlled with this signal turned ON.
[Related signals]
Tool alarm 1/tool skip tool (TAL1: Y788), tool alarm 2 (TAL2: Y789) and data count valid (TCEF:
Y78A)
B con-
Signal name
tact
TOOL CHANGE RESET
(L SYSTEM)
[Function]
This signal is used to clear all tool usage data in the group of the lathe system tool life management
II function.
[Operation]
Select whether the group to be cleared is all groups which have exceeded the life or specific group
with the tool group No. designation (file register R930).
When the next group is selected after this signal is input, the head tool of that group will be
selected.
(Note) The usage data will be counted in respect to the tool used when the signal is input until the
tool change is reset or until the next tool is selected when tool skip is carried out on the
currently selected group. Thus, when changing the selected tool along with the signal input,
select the group beforehand. However, if there is no movement command up to the next
group selection after this signal is input, a tool may not be selected because of the
preceding process. In this case, turn the "Recalculation request (CRQ)" signal ON before
selecting the group to invalidate the details of the preceding process.
[Related signals]
(1) Recalculation request (CRQ: Y72B)
(2) Tool group No. designation (R930)
6. EXPLANATION OF INTERFACE SIGNALS
6.3 PLC Output Signals (Bit Type: Y***)
Signal
abbreviation
TCEF
Signal
abbreviation
TLF1
Signal
abbreviation
TRST
6-3-72
1st system
2nd system
Y78A
Y86A
1st system
2nd system
Y78B
Y86B
1st system
2nd system
Y78C
Y86C
3rd system
Y94A
3rd system
Y94B
3rd system
Y94C