Mitsubishi Electric MELDAS C6 Interface Manual page 262

Cnc
Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

B con-
Signal name
tact
*
MANUAL FEEDRATE
[Function]
Feedrate in manual operation (JOG mode, INCREMENT mode, etc.) or in dry run of automatic
operation (memory or MDI) is selected.
[Operation]
This signal is valid in the following cases, but will be invalid when the rapid traverse signal (RT) is
ON.
(1) Jog mode, incremental mode or reference point return mode is ON.
(2) During cutting feed in automatic operation and "dry run" signal (DRN) is ON.
(3) Dry run signal is ON during rapid traverse in the automatic operation. Note that parameter "G00
dry run" must be ON.
These signals (*JV1~*JV16) are set with the code method. The relation is shown below.
*JV16
*JV8
*JV4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
1
1
0
1
1
0
1
1
0
1
0
1
1
0
1
1
0
1
1
0
1
1
0
0
1
0
0
1
0
0
1
0
0
0
1
1
0
1
1
0
1
1
0
1
1
0
1
0
0
1
0
0
1
0
0
1
0
0
0
1
0
0
1
0
0
1
0
0
1
0
0
0
0
0
0
0
0
0
If *JV 1 to *JV16 are all OFF, the previous value will be maintained. The value will be set to 0
when the power is turned OFF.
(Note 1) In JOG mode, true feedrate changes if this signal changes during feed motion.
(Note 2) In incremental feed mode, true feedrate does not change if this signal changes during feed
motion.
[Related signal]
(1) Manual feedrate method select (JVS: Y777)
(2) Manual override valid (OVSL: Y759)
6. EXPLANATION OF INTERFACE SIGNALS
6.3 PLC Output Signals (Bit Type: Y***)
Signal
abbreviation
*JV1~*JV16
Machine parameter set in meters
*JV2
*JV1
Metric mode
(mm/min)
1
1
1
0
0
1
0
0
1
1
1
0
0
1
0
0
1
1
1
0
0
1
0
0
1
1
1
0
0
1
0
0
100.00
1
1
140.00
1
0
200.00
0
1
270.00
0
0
370.00
1
1
520.00
1
0
720.00
0
1
1000.00
0
0
1400.00
1
1
2000.00
1
0
2700.00
0
1
3700.00
0
0
5200.00
1
1
7200.00
1
0
10000.00
0
1
14000.00
6-3-65
1st system
Y770~774
Manual feedrate
Machine parameter set in inches
Inch mode
(inch/min)
0.00
0.000
1.00
0.040
1.40
0.054
2.00
0.079
2.70
0.106
3.70
0.146
5.20
0.205
7.20
0.283
10.00
0.394
14.00
0.551
20.00
0.787
27.00
1.060
37.00
1.460
52.00
2.050
72.00
2.830
3.940
5.510
7.870
10.600
14.600
20.500
28.300
39.400
55.100
78.700
106.000
146.000
205.000
283.000
394.000
551.000
2nd system
3rd system
Y850~854
Y930~934
Metric mode
Inch mode
(mm/min)
(inch/min)
0.00
0.51
0.71
1.02
1.37
1.88
2.64
3.66
5.08
7.11
10.16
13.72
18.80
26.42
36.58
50.80
71.12
101.60
137.16
187.96
264.16
10.400
365.76
14.400
508.00
20.000
711.20
28.000
990.60
39.000
1371.60
54.000
1879.60
74.000
2641.60
104.000
3657.60
144.000
5080.00
200.000
7112.00
280.000
0.000
0.020
0.028
0.040
0.054
0.074
0.104
0.144
0.200
0.280
0.400
0.540
0.740
1.040
1.440
2.000
2.800
4.000
5.400
7.400