Mitsubishi Electric MELDAS C6 Interface Manual page 108

Cnc
Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

B con-
Signal name
tact
IN ZERO POINT
INITIALIZATION
[Function]
This signal is output when zero point initialization is being carried out in the absolute position
detection system.
[Operation]
The axis for which "1" is set in #0 INIT. SET on the [ABS. POSITION SET] screen is set to "1", and
is held until the power is turned OFF.
The stored stroke limit and stroke end signals are invalid while this signal is set to "1", and the
current limit during initialization is valid.
This signal is also set to "1" when the zero point initialization mode (AZS1~14) signal is ON.
B con-
Signal name
tact
ZERO POINT INITIALIZATION
INCOMPLETE
[Function]
This signal is output when the absolute position is not established in the absolute position detection
system.
[Operation]
This signal indicates that the zero point initialization has not been established once or that the
absolute position has been lost.
The stored stroke limit of the axis for which this signal is set to "1" in the absolute position detection
system is invalid.
6. EXPLANATION OF INTERFACE SIGNALS
6.1 PLC Input Signals (Bit Type: X***)
Signal
abbreviation
Signal
abbreviation
6-1-19
1st axis
2nd axis
X44C
X46C
1st axis
2nd axis
X44D
X46D
3rd axis
X48C
3rd axis