B con-
Signal name
tact
MANUAL RANDOM FEED
COMPLETE
[Function]
This signal is output when motion commanded in manual random feed mode is completed.
[Operation]
The signal turns ON when:
(1) Motion commanded in manual random feed mode is completed.
The signal turns OFF when:
(1) During motion in manual random feed mode.
(The signal stays OFF when motion is interrupted by "Reset & rewind" signal.)
(2) The power is turned ON.
[Timing chart]
Strobe (Y7AF)
In manual random feed
(X616)
Manual random feed
complete (X61C)
6. EXPLANATION OF INTERFACE SIGNALS
6.1 PLC Input Signals (Bit Type: X***)
Signal
abbreviation
CXFIN
Rising of "Strobe" signal is detected
and "In manual random feed" signal
is output. "Manual random feed
complete" signal turns off.
1st system
X61C
When manual random feed is completed
successfully, "Manual random feed
complete" signal turns on.
6-1-33
2nd system
3rd system
X69C
X71C