Mitsubishi Electric MELDAS C6 Interface Manual page 263

Cnc
Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

B con-
Signal name
tact
MANUAL FEEDRATE
METHOD SELECT
[Function]
When feedrate is specified in manual operation (JOG mode, incremental feed mode, etc.) or dry run
(automatic operation), feedrate command method is selected between code method and file
register method.
[Operation]
When the signal (JVS) is OFF, code method (*JV1~*JV16) is selected.
When the signal (JVS) is ON, file register method is selected.
Feedrate in automatic operation or
dry run (automatic operation)
(Note) For details of "code method" and "file register method", refer to the relevant description.
B con-
Signal name
tact
FEEDRATE LEAST
INCREMENT
[Function]
When manual feedrate is specified in file register mode (JVS: "ON") or in random manual feed
mode, file registers R (R904 and R905) are used. In this case, least increment of feedrate entered
into file registers R904 and R905 is specified by this signal.
[Operation]
The relationship between PCF1/PCF2 and least feed increment is as follows:
PCF2 PCF1
(mm/min or inch/min)
0
0
0
1
1
0
1
1
6. EXPLANATION OF INTERFACE SIGNALS
6.3 PLC Output Signals (Bit Type: Y***)
Signal
abbreviation
JVS
JVS
OFF: Code method
=
ON: File register method
Signal
abbreviation
PCF1, 2
Least increment
10
10mm/min (inch/min) when "1" is set in file registers.
1
1mm/min (inch/min) when "1" is set in file registers.
0.1
0.1mm/min (inch/min) when "1" is set in file registers.
0.01
0.01mm/min (inch/min) when "1" is set in file registers.
1st system
Y777
*JV1~*JV16 (0~14000mm/min)
File register (0~24000mm/min)
1st system
Y778, 779
Operation
6-3-66