Mitsubishi Electric MELDAS C6 Interface Manual page 128

Cnc
Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

B con-
Signal name
tact
F1-DIGIT COMMANDED
[Function]
This signal informs that the controller uses F1-digit commands (F1~F5) to control operation.
[Operation]
The signal turns ON when:
(1) F1-digit command (F1~F5) is selected for feedrate command currently being executed.
The signal turns OFF when:
(1) Block having a motion command specified with F1-digit code is completed.
(2) Operation is stopped by "Automatic operation "pause" command" signal (*SP) during execution
of F1-digit feedrate command.
(3) Operation is stopped by "Interlock" signal during execution of F1-digit feedrate command, or
(4) Reset condition occurs.
(For details of reset conditions, refer to the description about "In auto operation "run"" signal
(OP).)
(Note 1) The setup parameter, base specification parameter "#1079 F1digt" must be validated and
"#1185~#1189 speed during F1-digit command" must be set to use the F1-digit command.
[Related signal]
(1) F1-digit No. (F11~F14)
B con-
Signal name
tact
IN TOOL LIFE MANAGEMENT TLFO
[Function]
This signal is output while tool life is being managed.
[Operation]
The signal turns ON when the parameter "#1103 T_Life" is ON.
6. EXPLANATION OF INTERFACE SIGNALS
6.1 PLC Input Signals (Bit Type: X***)
Signal
abbreviation
F1DN
Signal
abbreviation
6-1-39
1st system
2nd system
X62A
X6AA
1st system
2nd system
X62B
X6AB
3rd system
X72A
3rd system
X72B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t