CHAMFERING
[Function]
In thread cutting cycle, chamfering can be ignored.
[Operation]
Status of this signal is determined at start of thread cutting cycle.
(1) CHAMFERING (*CDZ) is OFF.
Chamfering (at end of thread cutting) is accomplished.
(2) CHAMFERING (*CDZ) is ON.
Chamfering is not accomplished (signal is ignored).
6. EXPLANATION OF INTERFACE SIGNALS
6.3 PLC Output Signals (Bit Type: Y***)
Signal
abbreviation
*CDZ
Chamfer section
Thread section
Thread section
6-3-41
1st system
2nd system
Y71B
Y7FB
Tool nose path
Tool nose path
3rd system
Y8DB