B con-
Signal name
tact
IN REWIND
[Function]
This signal informs that the controller is indexing the memory mode.
[Operation]
The signal turns ON when "Reset & rewind" signal (RRW) is turned ON by the PLC in memory
mode (with M02 or M30 command), and turns OFF when the controller completes indexing the
program in execution.
(Note 1) Since indexing of program in memory mode ends immediately, it may not be verified by
user PLC.
[Related signals]
Reset & rewind (Y71A)
6. EXPLANATION OF INTERFACE SIGNALS
6.1 PLC Input Signals (Bit Type: X***)
Signal
abbreviation
RWD
6-1-29
1st system
2nd system
X617
X697
3rd system
X717