5 Technical data

5.1.1

Device types

Reed or transistor (with connected turbine meter)
Pulse input
Current output
Wiegand (with connected turbine meter)
Use
Pulse input
Current output
5.1.2

Inputs

Volume
Reed
Pulse frequency
Pulse width
Voltage
Wiegand
Pulse frequency
Pulse width
Voltage
5.1.2.1
Power supply
Power supply
Internal battery
External 6-24 V DC via X6
External 6-10.5 V DC via X6
External 6-24 V DC via X9
Reed or transistor
Current loop connection
(current supply via this current output possible)
Direct installation on the TME 400 turbine meter instead
of the meter head
Wiegand
Current loop connection
(current supply via this current output possible)
0 Hz ... 4 Hz
≥ 20 ms
low: ≤ 0.9 V
high: ≥ 2.2 V
0 Hz ... 400 Hz; with battery operation
≥ 5 µs
min. 1 V
max. 5 V (determined by sensor)
Lithium cell 3.6 V; in the device (battery pack)
via U
+ battery pack (
ext
via U
+ battery pack (
ext
via current loop connection + battery pack
5 Technical data
NON-Ex)
Ex)
Manual TME400-VMF · EN11 · January 22nd, 2024