Technical Data; Device Types; Inputs; Power Supply - RMG TME400-VM VMF Series Operating Manual

Turbine meter
Hide thumbs Also See for TME400-VM VMF Series:
Table of Contents

Advertisement

5 Technical data

5. Technical data
5.1.1.
Reed or transistor (with connected turbine meter)
70
Pulse input
Current output
Wiegand (with connected turbine meter)
Use
Pulse input
Current output
5.1.2.
Volume
Reed
Pulse frequency
Pulse width
Voltage
Wiegand
Pulse frequency
Pulse width
Voltage
5.1.2.1.

Power supply

Internal battery
External 6-24 V DC via X6
External 6-10.5 V DC via X6
External 6-24 V DC via X9
Manual TME400-VMF · EN07 · December, 7

Device types

Reed or transistor
Current loop connection
(current supply via this current output possible)
Direct installation on the TME400 turbine meter instead
of the meter head
Wiegand
Current loop connection
(current supply via this current output possible)

Inputs

0 Hz ... 4 Hz
³ 20 ms
low: £ 0.9 V
0 Hz ... 400 Hz; with battery operation
³ 5 µs
min. 1 V
Power supply
th
high: ³ 2.2 V
max. 5 V (determined by sensor)
Lithium cell 3.6 V; in the device (battery pack)
via U
+ battery pack (
ext
via U
+ battery pack (
ext
via current loop connection + battery pack
2020
NON-Ex)
Ex)