Current Output - RMG TME400-VM VMF Series Operating Manual

Turbine meter
Hide thumbs Also See for TME400-VM VMF Series:
Table of Contents

Advertisement

B09
Maximum time > Qug + Indicates the maximum time until the flow rate (e.g. on start-up )
Coor-
Name
dinate
B02
Operating flow rate
B03
Frequency
B05
Min. flow rate
B06
Max. flow rate
B10
Coefficient A-2
B11
Coefficient A-1
B12
Coefficient A0
B13
Coefficient A1
B14
Coefficient A2
B15
Max. operating point de-
viation
B08
Leak flow volume limit
B09
Maximum time > Qug +

Current output

4.3.3.3.
Coordi-
Name
nate
F01
Current
F02
Current mode
F03
Current source
reaches the measuring range (Qmin) after reaching the lower meas-
uring limit (Qug). The flow rate measurement applies as defective
during this time, but no error message is generated.
Modbus
Modbus
Protec-
register
access
tion
320
R
A
322
R
A
521
W
E
523
W
E
530
W
E
532
W
E
534
W
E
536
W
E
538
W
E
540
W
E
527
W
E
529
W
E
Description
Current to be output
0
Off (default)
1
No errors
2
Error 3.5 mA
3
Error 21.8 mA
4
0 - 20mA
If the current mode is "0", meaning "Off", in apart from parameter
F02: current mode, no additional parameters of the output are visible
or adjustable.
0
Specification (default)
1
Operating flow rate
2
Frequency
3
Calibration 4mA
4
Calibration 20mA
Data
Min. Max.
type
float
-
-
float
-
-
float
*
*
float
*
*
float
*
*
float
*
*
float
*
*
float
*
*
float
*
*
float
0.0
100.0
float
*
*
uint16
0
10000
Manual TME400-VMF · EN07 · December, 7
4 Operation
61
Default Unit
m
3
/h
*
Hz
*
m
3
/h
0.0
1000.0 m
3
/h
Am2
0
Am1
0
A0
0
-4
A1x10
0
-8
A2x10
0
kkp
2.0
3
m
/h
*
s
10
th
2020