Danfoss VLT Automation Drive FC 360 Programming Manual page 137

Table of Contents

Advertisement

Parameter Lists
Par. No. #
Parameter description
14-32
Current Lim Ctrl, Filter Time
14-4* Energy Optimising
14-40
VT Level
14-41
AEO Minimum Magnetisation
14-44
d-axis current optimization for IPM
14-5* Environment
14-50
RFI Filter
14-51
DC-Link Voltage Compensation
14-52
Fan Control
14-55
Output Filter
14-6* Auto Derate
14-61
Function at Inverter Overload
14-63
Min Switch Frequency
Dead Time Compensation Zero
14-64
Current Level
Speed Derate Dead Time Compen-
14-65
sation
14-8* Options
14-89
Option Detection
14-9* Fault Settings
14-90
Fault Level
5.2.14 15-** Drive Information
Par. No. #
Parameter description
15-0* Operating Data
15-00
Operating hours
15-01
Running Hours
15-02
kWh Counter
15-03
Power Up's
15-04
Over Temp's
15-05
Over Volt's
15-06
Reset kWh Counter
15-07
Reset Running Hours Counter
15-3* Alarm Log
15-30
Alarm Log: Error Code
15-31
InternalFaultReason
15-4* Drive Identification
15-40
FC Type
15-41
Power Section
15-42
Voltage
15-43
Software Version
15-44
Ordered TypeCode
15-45
Actual Typecode String
15-46
Drive Ordering No
15-48
LCP Id No
15-49
SW ID Control Card
15-50
SW ID Power Card
MG06C602
Programming Guide
Default value
4-set-up
5 ms
All set-ups
66%
All set-ups
66%
All set-ups
100%
All set-ups
[2] Grid Type
1 set-up
[1] On
All set-ups
[5] Constant-on mode
1 set-up
[0] No Filter
1 set-up
[0] Trip
All set-ups
[2] 2.0 kHz
1 set-up
[0] Disabled
All set-ups
ExpressionLimit
All set-ups
[0] Protect Option
Config.
1 set-up
[3] Trip Lock
All set-ups
Default value
2-set-up
0 h
1 set-up
0 h
1 set-up
0 kWh
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
[0] Do not reset
1 set-up
[0] Do not reset
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
All set-ups
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
Danfoss A/S © 7/2015 All rights reserved.
Change
Conversion
during
index
operation
TRUE
-4
FALSE
0
FALSE
0
TRUE
0
FALSE
-
FALSE
-
TRUE
-
FALSE
-
TRUE
-
FALSE
-
FALSE
-
FALSE
0
TRUE
-
TRUE
-
Change
Conversion
during
index
operation
TRUE
74
TRUE
74
TRUE
75
TRUE
0
TRUE
0
TRUE
0
TRUE
TRUE
TRUE
0
TRUE
0
FALSE
0
VisStr[7]
FALSE
0
VisStr[20]
FALSE
0
VisStr[20]
FALSE
0
VisStr[20]
FALSE
0
VisStr[41]
FALSE
0
VisStr[40]
FALSE
0
VisStr[9]
FALSE
0
VisStr[21]
FALSE
0
VisStr[21]
FALSE
0
VisStr[21]
Type
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
5
5
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Type
Uint32
Uint32
Uint32
Uint32
Uint16
Uint16
Uint8
Uint8
Uint8
Int16
135

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT Automation Drive FC 360 and is the answer not in the manual?

Questions and answers

Table of Contents