Parameter Descriptions
4.16 Parameters: 17-** Feedback Options
4.16.1 17-1* Inc.Enc.Interface
17-10 Signal Type
Option:
[0]
None
[1]
RS422 (5V TTL)
*
4
4
[2]
Sinusoidal 1Vpp
17-11 Resolution (PPR)
Range:
1024
[10 - 10000 ] Enter the resolution of the incremental
*
4.16.2 17-5* Resolver Interface
17-50 Poles
Range:
2
[2 - 2 ]
*
17-51 Input Voltage
Range:
7 V
*
17-52 Input Frequency
Range:
10 kHz
*
17-53 Transformation Ratio
Range:
0.5
*
17-56 Encoder Sim. Resolution
Option:
[0]
*
[1]
[2]
[3]
[4]
17-59 Resolver Interface
Option:
[0]
*
[1]
106
Function:
Function:
track, which is the number of pulses or
periods per revolution.
Function:
Function:
[2 - 8 V]
Function:
[2 - 15 kHz]
Function:
[0.1 - 1.1 ]
Function:
Disabled
512
1024
2048
4096
Function:
Disabled
Enabled
Danfoss A/S © 7/2015 All rights reserved.
®
VLT
AutomationDrive FC 360
4.16.3 17-6* Monitoring and App.
17-60 Feedback Direction
Option:
[0]
*
[1]
17-61 Feedback Signal Monitoring
Option:
[0]
[1]
*
[2]
[3]
[4]
[5]
[6]
Clockwise
Counter clockwise
Disabled
Warning
Trip
Jog
Freeze Output
Max Speed
Switch to Open Loop
Function:
Function:
MG06C602