Danfoss VLT Automation Drive FC 360 Programming Manual page 30

Table of Contents

Advertisement

Parameter Descriptions
Parameter 2-02 DC Braking Time
Parameter 2-04 DC Brake Cut In Speed [Hz]
Parameter 2-06 Parking Current
Parameter 2-07 Parking Time
Parameter 2-10 Brake Function
Parameter 2-16 AC brake Max. Current
Parameter 2-17 Over-voltage Control
Parameter 4-10 Motor Speed Direction
4
4
Parameter 4-14 Motor Speed High Limit [Hz]
Parameter 4-18 Current Limit
Parameter 4-19 Max Output Frequency
Parameter 4-58 Missing Motor Phase Function
Parameter 14-01 Switching Frequency
Parameter 14-03 Overmodulation
Parameter 14-07 Dead Time Compensation Level
Parameter 14-08 Damping Gain Factor
Parameter 14-09 Dead Time Bias Current Level
Parameter 14-10 Mains Failure
Parameter 14-11 Mains Voltage at Mains Fault
Parameter 14-12 Function at Mains Imbalance
Parameter 14-27 Action At Inverter Fault
Parameter 14-40 VT Level
Parameter 14-41 AEO Minimum Magnetisation
Parameter 14-50 RFI Filter
Parameter 14-51 DC-Link Voltage Compensation
Parameter 14-55 Output Filter
Parameter 14-64 Dead Time Compensation Zero Current Level
Parameter 14-65 Speed Derate Dead Time Compensation
Parameter 30-22 Locked Rotor Detection
Parameter 30-23 Locked Rotor Detection Time [s]
Table 4.2 Active Parameters
1-10 Motor Construction
Option:
[0]
Asynchron
*
[1]
PM, non-
salient SPM
[2]
PM, salient
IPM, non Sat.
[3]
PM, salient
IPM, Sat.
1-14 Damping Gain
Range:
120
[ 0 -
%
250 %]
*
28
VLT
Function:
For asynchronous motors.
For permanent magnet (PM) motors with
surface-mounted (non-salient) magnets.
Refer to parameter 1-14 Damping Gain to
parameter 1-17 Voltage filter time const. for
details about optimising the motor
operation.
For permanent magnet (PM) motors with
interior (salient) magnets, without
inductance saturation control.
For permanent magnet (PM) motors with
interior (salient) magnets, with inductance
saturation control.
Function:
The damping gain stabilises the PM machine. The
value of damping gain controls the dynamic
performance of the PM machine. High damping
gain gives high dynamic performance and low
Danfoss A/S © 7/2015 All rights reserved.
®
AutomationDrive FC 360
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1-14 Damping Gain
Range:
1-15 Low Speed Filter Time Const.
Range:
Size related
*
1-16 High Speed Filter Time Const.
Range:
Size related
*
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Function:
damping gain gives low dynamic performance.
The dynamic performance is related to the
machine data and load type. If the damping gain
is too high or low the control becomes unstable.
Function:
[ 0.01 - 20
This time constant is used below
s]
10% rated speed. Obtain quick
control through a short damping
time constant. However, if this value
is too short, the control becomes
unstable.
Function:
[ 0.01 - 20
This time constant is used above
s]
10% rated speed. Obtain quick
control through a short damping
time constant. However, if this value
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
MG06C602

Advertisement