Symptom:
POWER TOP SWITCH STUCK
When Monitored and Set Condition:
POWER TOP SWITCH STUCK
When Monitored: Whenever the ignition is on.
Set Condition: Normal operation of this switch consists of pressing it for only a few
seconds. If the BCM detects the switch stuck in a depressed condition for more than 28
seconds, this code will set and the BCM will ignore the input until the condition is
corrected.
DTC PRESENT
POWER TOP SWITCH STUCK
CONVERTIBLE TOP SWITCH MUX WIRE SHORT TO GROUND
BODY CONTROL MODULE - CONVERTIBLE TOP SWITCH MUX
TEST
1
With the DRBIII , erase DTCs.
Turn the ignition on.
Operate the power top in all positions including the 4 window drop position.
With the DRBIII , read DTCs.
Does the DRBIII display POWER TOP SWITCH STUCK?
Yes → Go To 2
→ Check the switch for a possible sticking condition. Using the
No
2
Disconnect the Power Top Switch connector.
With the DRBIII , erase DTCs.
Cycle the ignition switch from OFF to ON.
Wait one minute.
With the DRBIII , read DTCs.
Does the DRBIII display POWER TOP SWITCH STUCK?
Yes → Go To 3
→ Replace the Power Top Switch.
No
POSSIBLE CAUSES
ACTION
wiring diagram/schematic as a guide, inspect the wiring and
connectors for a possible intermittent short to ground.
Perform BODY VERIFICATION TEST - VER 1.
Perform BODY VERIFICATION TEST - VER 1.
435
POWER TOP
APPLICABILITY
All
All