AIRBAG
Symptom:
LOSS OF IGNITION RUN - START
When Monitored and Set Condition:
LOSS OF IGNITION RUN - START
When Monitored: With the ignition in the Run-Start position the ACM monitors the
Fused Ignition Switch Output Run-Start circuit for proper system voltage.
Set Condition: If the voltage on the Fused Ignition Switch Output Run-Start circuit drops
below approximately 6.0 volts, the code will set.
FUSED IGNITION SW OUTPUT RUN-START SHORT TO GROUND
IGNITION SWITCH RUN - START CIRCUIT OPEN
FUSED IGNITION SWITCH OUTPUT RUN-START CIRCUIT OPEN
ACM, FUSED IGNITION OUTPUT RUN-START CIRCUIT OPEN
ACM, RUN - START SHORTED TO GROUND
FUSED IGNITION SWITCH OUTPUT RUN - START CIRCUIT SHORT TO GROUND
STORED CODE OR INTERMITTENT CONDITION
ACTIVE CODE PRESENT
TEST
1
Ensure the battery is fully charged.
Turn the ignition on.
NOTE: For the purpose of this test, the AECM and ORC modules will be
referred to as an ACM.
DETERMINE ACTIVE OR STORED DTC:
ACM - ACTIVE DTC
ACM - STORED DTC
NOTE: When reconnecting Airbag system components, the ignition must be
turned off and the battery must be disconnected.
2
Turn Ignition off.
Remove and inspect the Airbag Run - Start Fuse.
NOTE: Check connectors - Clean and repair as necessary.
Is the Fuse open?
Yes → Go To 3
→ Go To 5
No
POSSIBLE CAUSES
ACTION
Go To 2
Go To 8