POWER DOOR LOCKS/RKE
DECKLID RELEASE SOLENOID OUTPUT FAILURE —
TEST
3
Turn the ignition off.
Disconnect the Decklid Release Solenoid/Ajar Switch harness connector.
Disconnect the Body Control Module C4 connector.
Turn the ignition on.
Measure the voltage of the Decklid Release Solenoid Driver circuit in the Decklid
Release Solenoid connector.
Is there any voltage present?
Yes → Repair the Decklid Release Solenoid Driver circuit for a short to
→ Go To 4
No
4
If there are no possible causes remaining, view repair.
Repair
5
Turn the ignition off.
Disconnect the Decklid Release Solenoid/Ajar Switch harness connector.
Measure the resistance between ground and the ground circuit.
Is the resistance below 5.0 ohms?
Yes → Go To 6
→ Repair the ground circuit for an open.
No
6
Turn the ignition off.
Disconnect the Decklid Release Solenoid/Ajar Switch harness connector.
Connect a 12-volt Test Light between the Decklid Release Solenoid Driver ckt and the
ground circuit (cavs 1 and 3).
Press the decklid release switch several times and observe the test light.
Did the test light illuminate when the switch was pressed?
Yes → Replace the Decklid Release Solenoid.
→ Go To 7
No
7
Turn the ignition off.
Disconnect the Decklid Release Solenoid/Ajar Switch harness connector.
Disconnect the Body Control Module C4 connector.
Measure the resistance between ground and the Decklid Release Solenoid Driver
circuit.
Is the resistance below 5.0 ohms?
Yes → Repair the Decklid Release Solenoid Driver circuit for a short to
→ Go To 8
No
ACTION
voltage.
Perform BODY VERIFICATION TEST - VER 1.
Replace the Body Control Module.
Perform BODY VERIFICATION TEST - VER 1.
Perform BODY VERIFICATION TEST - VER 1.
Perform BODY VERIFICATION TEST - VER 1.
ground.
Perform BODY VERIFICATION TEST - VER 1.
398
Continued
APPLICABILITY
All
All
All
All
All