03-58
18) Flasher (Blinking) Function
Turn signal lamp control
1.
When the BCM is received the multifunction switch signal, it operates the turn signal lamp
and interior buzzer with the intervals of 400 ms ON/400 ms OFF for 75 times/min.
2.
The turn signal lamps are operational only when IGN1 is ON.
3.
If the turn signal lamp is defective during its operation, the turn signal lamp blinks with the
intervals of 300 ms ON/300 ms OFF for 100/min and the interior buzzer sounds with same
interval.
4.
Defective conditions by BCM: Open - below load of 3.0 A, Short - over load of 7.0 A (load
means lamp load here)
5.
When turning ON the turn signal switch, the lamp blinks 3 times by the BCM. When turning OFF
the switch during the operation, the turn signal lamp blinks 3 times and goes off.
6.
When turning OFF and then immediately ON the turn signal switch during auto blinking
operation of 3 times, the turn signal lamp blinks additional 3 times.
7.
When turning ON another turn signal switch during the operation, currently operated turn signal
lamp stops immediately and another turn signal lamp starts blinking.