03-62
Emergency hazard flasher control (coupled with ABS)
1.
System layout
2.
Operating conditions: When receiving the emergency hazard flasher ON signal from ESP and
ABS.
When receiving the emergency stop signal through PCAN communication it blinks with the
interval of 4 Hz and when receiving the emergency stop OFF signal through PCAN
communication it blinks with the interval of 1.25 Hz, normal operating speed.
However, the manual operation of the switch has a priority over this function.
-
Priority
Manual hazard flasher > Emergency stop signal > Emergency auto hazard flasher > Auto
hazard flasher
(If emergency stop signal is received through PCAN communication during hazard flasher
operation, the signal is overridden. If the emergency hazard flasher signal is received
during multi-function automatic hazard flasher operation or multi-function automatic
hazard flasher is received during emergency hazard flasher operation, emergency stop is
-
performed.)
When the emergency stop signal is received, the hazard flasher blinks with the interval of 4
Hz, then returns to normal operation speed. After that, if the emergency stop signal is
received again, the emergency hazard flasher blinks with the interval of 4 times/sec.