SSANGYONG Korando 2012 Manual page 294

Hide thumbs Also See for Korando 2012:
Table of Contents

Advertisement

3. INPUT/OUTPUT DEVICES
1.
Front temperature sensor: This sensor is installed at the inlet of DOC and detects whether the
DOC can burn (oxidize) the post-injected fuel or not.
2.
Rear temperature sensor: This sensor is installed at the inlet of DPF and monitors that the
temperature of the exhaust gas is kept at 600℃.
-
If the temperature exceeds 600℃, the life of CDPF can be reduced. So the amount of fuel
post-injection is decreased.
-
If the temperature drops under 600℃, the rate of regeneration can be decreased. So the
amount of fuel post-injection is increased.
3.
Differential pressure sensor: This sensor checks the amount of PM collected by calculating the
pressure difference between before and after the CDPF.
4.
Electric throttle valve: This valve reduces the intake air flow to raise the temperature of the
exhaust gas when the CDPF is operating during idling.
14-9
1114-00

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents