(5) Horn relay
The power for the theft deterrent horn relay is supplied to the ICM terminal no. C5 through the
battery SB1 and fuse no. 45 in the interior fuse box.
The relay is operated by the signals from the BCM terminal no. A24. Refer to Conditions For Theft
Deterrent for operating conditions.
(6) Tailgate relay
The power for the tailgate relay is supplied to the ICM terminals no. C10 and no. B5 through the
battery SB1 and fuse no. 42 in the interior fuse box. The relay is operated (i.e. ON/OFF) by the
operation signal from the BCM terminal no. D6.
Deactivation condition
-
Without SKM
The tailgate open relay is turned OFF immediately after the driver's door is locked or the
vehicle speed becomes 3 km/h or more during its activation.
-
With SKM
Refer to the section Tailgate of BCM for the operating conditions.