5) Illumination & Brightness
(1) Operations for Power Supply
Operations for power supply in SVC
1.
When the ignition switch is turned to ON position, the message "WELCOME" is displayed for 2
seconds on the DOT LCD and the seat belt reminder comes on for 4 seconds. However, if a
signal with higher priority is received, the seat belt reminder comes on only for 2 seconds to
display it.
2.
The pre-warning (system check) indicator comes on for 4 seconds and goes off 0.4 seconds
after that the ignition is switched on.
3.
All input signals can be input 4 seconds after the pre-warning (system check) indicator starts
illuminating.
4.
Only the symbol and DOT LCD are illuminated initially, if the SKM (Smart Key Module) or door
(B-CAN) signal is received
while B+ power is supplied.
If the ignition is switched on with the LCD illuminated, the DOT LCD and the symbol follow
the side fascia panel.
5.
When the step 1, 2 and 3 are performed after 4 seconds, the seat belt warning lamp is
deactivated in advance.
6.
Dial light ON condition: Lights up gradually for 2 seconds when the ignition is switched on.
05-25