8.4
Activate the factory settings
Introduction
Prior to making factory settings, make sure that the PLC has stopped sending enables to the
drive.
Procedure for activating factory settings
1. These can be found in the "Commissioning > Drive systems > Drive units" menu.
2. Press the softkey "Control Unit MD".
3. Select the NCU or NX, for which factory settings have to be established, with the vertical
4. To check when activation of factory settings has ended, select parameter r3988 for
5. Press the "Save/Reset" vertical softkey.
6. Select "Factory settings" and confirm the prompt "Do you really want to...?" with "Yes".
7. Communication is lost temporarily. During this time a "#" is displayed for machine values..
8. Boot-state check: If r3988 = 200H, save the factory settings using the "Save" softkey.
9. Wait until the message line displays "Drive [drive name (drive number)] saved".
10. Switch off system (drive set de-energized).
11. Switch system back on in order to bring all SINAMICS components to one uniform
CNC Part 1 (NCK, PLC, drive)
Commissioning Manual, 11/2006, 6FC5397-2AP10-2BA0
softkeys "Drive unit+/Drive-".
monitoring.
firmware revision level in the next step.
Commissioning SINAMICS drives
8.4 Activate the factory settings
69