Nck Utilization - Siemens SINUMERIK 804D sl Commissioning Manual

Cnc part 1 nck, plc, drive
Table of Contents

Advertisement

NCK start-up
10.2 System data
10.2.9

NCK utilization

Introduction
You can view utilization of system resources for the NCK on the HMI under the menu
"Diagnostics > Service displays > System resources".
Figure 10-2
The following machine data is taken into consideration for displayed runtimes (see Chapter
Cycle times (Page 108) ):
• MD1061 POSCTRL_CYCLE_TIME = MD10050 SYSCLOCK_CYCLE_TIME (System
• MD1070 IPO_SYSCLOCK_TIME_RATIO (factor for interpolation cycle)
• MD1071 IPO_CYCLE_TIME (interpolation cycle)
What will be displayed?
In the display of the "System resources" menu, the values have the following meaning:
• Area "Nett runtime (purely CPU time)":
• Area "Gross runtime (time from start to end)":
• Line "NCU load by position controller and interpolator":
112
NC utilization
basic cycle)
Active times (current, minimum and maximum) are displayed in the nett values.
The relation to the machine data can be seen from the displayed values.
The corresponding total utilization of the system (position controller + interpolator) is
displayed, based on the net values.
CNC Part 1 (NCK, PLC, drive)
Commissioning Manual, 11/2006, 6FC5397-2AP10-2BA0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120Sinumerik 840de sl