PLC commissioning
7.1 Creating a SIMATIC S7 project
Steps for PROFIBUS DP
1. You used the left mouse button to select NCU 720.1 and while holding down the mouse
2. After you release the mouse button, configure the properties of PROFIBUS DP interface
Figure 7-4
3. This is an Ethernet machine control panel, which does not require configuration. Select
4. Module NCU 720.1 with SINAMICS S120 is inserted into the HW config (see figure
Note
With the <F4> key and confirmation of the question regarding "Reorganize", you can
reorganize the display in the station window.
46
button you dragged it to the "Station design" station window.
for socket X126 (machine control panel) in the dialog box (see figure below).
Properties of PROFIBUS DP
"Cancel".
below).
CNC Part 1 (NCK, PLC, drive)