9.3 External Connections

Camera I/O Connector

■ Lens Connector
Used to connect each type of lens. The connector pin assignment differs among camera lens mount types.
-------- Receptacle --------
9
1
8
2
10
7
12
11
6
4
5
Insertion Side
[BTA Mount]
Pin No.
Name
1
RET ON
2
VTR TRIG
3
GND
4
IRIS SERVO
5
IRIS CONT
6
+12V LENS
7
IRIS FOLLOW
(continues to the next page)
224
3
Camera side : HR10A-10R-12SC
Cable side
Function
RETURN VIDEO ON/OFF signal
RETURN ON: 0.5V or less Zout = 10M Ω or more
RETURN OFF: OPEN Zout = 1.5k Ω or less
Zin = 100k Ω ± 5% (10kΩ or more)
Momentary operation
VTR START/STOP signal
VTR START: 0.5V or less Zout = 10M Ω or more
VTR STOP: OPEN Zout = 1.5k Ω or less
Zin = 100k Ω ± 5% (10kΩ or more)
Momentary operation
Grounding for LENS
Forced IRIS servo ON/OFF
SERVO ON
: +5V ± 0.5V
Zout = 10k Ω or less
SERVO OFF
: 0.5V or less
Zout = 1.5k Ω or less
or 100k Ω or more
Control output of lens iris
F2.8
: 6.2V ± 0.05V
(6.2V ± 0.1V)
F16
: 3.4V ± 0.05V
(3.4V ± 0.1V)
CLOSE : 2.5V ± 0.2V
(2.1V to 2.9V)
Zout = 1k Ω ± 10% (Fixed)
DC+12V output for LENS
Normal operation range:
DC+10V - +20V
(DC+10V - +17V)
Control output of lens iris
F2.8
: 6.2V ± 0.05V
(6.2V ± 0.1V)
F 16
: 3.4V ± 0.05V
(3.4V ± 0.1V)
CLOSE : 2.5V ± 0.2V
(2.1V to 2.9V)
Zin = 100k Ω ± 2% (100k Ω or more)
UHK-430/CCU-430 1710 VER2 (E)
(12-pin male plug)
: HR10A-10P-12PC
I/O
External Interface
1
IN
V≦0.5V
2
IN
V≦0.5V
GND
4
OUT
V≦0.5V
OUT
OUT
IN
V=5V±0.5V