Ikegami CCU-430 Operation Manual page 219

4k/hd portable camera system
Table of Contents

Advertisement

Diagnosed Item
Cable Connection
Optical fiber composite camera
cable connection status between the
camera and the CCU
Safety signal
Status of the safety signal sent from
the camera to the CCU
Camera ID
Status of the model identification
signal sent from the camera to the
CCU
Genlock
Status of external SYNC signal
Note:
8.1 Alarm Lamp on the OCP or MCP Flashes ON and OFF
Description
Diagnosis Result
OK
OPEN
SHORT
OK
NG
OK
NG
INT
1080P59
1080I59
1080P23
1080P23SF
1080P29
720P59
1080P50
1080P25
1080I50
720P50
UNKNOWN
UHK-430/CCU-430 1710 VER2 (E)
Meaning
Normal
Cable is not connected, or there is an open.
A short circuit occurs in the cable.
Normal
The safety signal is not received, or the
connected camera is not supported by this
CCU.
Normal
The model identification signal is not received,
or the connected camera is not supported by
this CCU.
No external SYNC signals are input (operation
is performed with internal SYNC signals.)
Internal mode
When external SYNC signal is 1080P59.94
When external SYNC signal is 1080i59.94
When external SYNC signal is 1080P23.98
When external SYNC signal is 1080P23.98SF
When external SYNC signal is 1080P29.97
When external SYNC signal is 720P59.94
When external SYNC signal is 1080P50
When external SYNC signal is 1080P25
When external SYNC signal is 1080i50
When external SYNC signal is 720P50
External synchronization signals have been
input, but cannot be identified.
8
201

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uhk-430

Table of Contents