■ FULL Auto Setup
The FULL auto setup can be activated from the camera menu, CCU front side, OCP, or MCP. This section explains how to activate
from the camera menu.
1
Shoot an external auto setup chart.
whole chart.
2
Use the CC FILTER switch and ND FILTER switch on the right side of the camera to set the optical filter which
suits the light source.
3
Select and activate "FULL" from the camera menu "AUTO SETUP MODE" - "AUTO SETUP".
Note:
next procedures.
1. Press the SETUP button in the function switch part.
3. Press the Full button on the LCD.
4. Press the Start button on the LCD.
■ LEVEL Auto Setup
The LEVEL auto setup can be activated from the camera menu, CCU front side, OCP, or MCP. This section explains how to
activate from the camera menu.
1
Shoot an external auto setup chart.
whole chart.
2
Use the CC FILTER switch and ND FILTER switch on the right side of the camera to set the optical filter which
suits the light source.
3
Select and activate "LEVEL" from the camera menu "AUTO SETUP MODE" - "AUTO SETUP".
Note:
next procedures.
1. Press the SETUP button in the function switch part.
3. Press the Level button on the LCD.
4. Press the Start button on the LCD.