8.1 Alarm Lamp on the OCP or MCP Flashes ON and OFF
■ List of Self Diagnostic Information
List of Self Diagnostic Information
Diagnosed Item
Camera Power
Power status of the camera
Camera Fan
Rotating status of fan of the camera
Camera Temp
Internal temperature of the camera
Camera Battery
Status of the battery in the MPROC
module of the camera
Camera Memory
Status of the RAM in the MPU module
of the camera
CCU Fan
Rotating status of the fans on the rear
and inside of the CCU
CCU Temp
Internal temperature of the CCU
CCU Battery
Status of the battery in the CCU MPU
module and TRX_VP module
CCU Memory
Status of the RAM in the CCU MPU
module and TRX_VP module
CCU >>>
OPT Level
Optical signal level sent from the CCU
Camera
to the camera (Detect the optical
(CCU to
receiving level at the camera side and
Camera
display the status).
transmission)
SDI Status
Monitors the data transmission status
between CCU and the camera.
Comm Status Status of the command signal sent
from the CCU to the camera
Camera >>>
OPT Level
Optical signal level sent from the
CCU
camera to the CCU (Detect the optical
(Camera
receiving level at the CCU side and
to CCU
display the status).
transmission)
SDI Status
Monitors the data transmission status
between CCU and the camera.
Comm Status Status of the command signal sent
from the camera to the CCU
200
Description
Diagnosis Result
ON
OFF
AUTO SSLOW
AUTO SLOW
AUTO NOR
AUTO FAST
FAST
NG
OK
NG
OK
NG
OK
NG
OK
NG
OK
NG
OK
NG
OK
NG
OK
ATTEN
WARN
NG
OK
NG
OK
NG
OK
ATTEN
WARN
NG
OK
NG
OK
NG
UHK-430/CCU-430 1710 VER2 (E)
Meaning
The camera is powered ON.
The camera is powered OFF.
Super-slow in auto mode
Slow in auto mode
Normal in auto mode
Fast in auto mode
Fast in manual mode
Fan has stop.
Normal
The internal temperature is abnormally.
Normal
The backup battery voltage is low.
Normal
Data in the module is abnormally.
Normal
Internal cooling fan either has stopped.
Normal
The internal temperature is abnormally.
Normal
The backup battery voltage is low.
Normal
Data in the module is destroyed.
Good
The amount of light received decreased.
The amount of light received significantly
decreased.
Light cannot be received.
Normal
Detect CRC error
Normal
No command signals are sent, or a CPU error
occurs.
Good
The amount of light received decreased.
The amount of light received significantly
decreased.
Light cannot be received.
Normal
Detect CRC error
Normal
No command signals are sent, or a CPU error
occurs.