Replacing Fuses - Ikegami CCU-430 Operation Manual

4k/hd portable camera system
Table of Contents

Advertisement

8.6

Replacing Fuses

may occur such as the power supply disabled to be turned on, the power not transmitted to the camera, or the power alternately
transmitted and stopped repeatedly to the camera. In such case, the fuse might be blown. If that occurs, replace the fuse by taking
the following procedure.
1
Make sure the MAIN POWER switch on the front of the CCU is turned "OFF."
2
Use a flat-blade screwdriver or the like to press and turn the fuse on the front of the CCU counterclockwise and
remove it.
3
Insert a new fuse into the fuse cap and turn it clockwise using a flat-blade screwdriver or the like until it seats
firmly.
CAUTION:
Fuse to be used
("T" in the rating indicates a time lag fuse.)
CCU front view
CABLE STATUS
ID
TALLY
NORMAL
OPEN
SHORT
OPT RX LEVEL
CAM
CCU
INTERCOM
PHONE
MIC
ON
OFF
PTT
CALL
INIT/PM
CAM: 400V T5A
AC line fuses for transmitting power to the camera head
UHK-430/CCU-430 1710 VER2 (E)
8.6 Replace Fuses
ALARM
CAM:400V T5A
COMM
TEMP
FAN
CCU STATUS
GENLOCK
APC
SDI
POWER
MENU
CAM
CCU
PRV
OPE
COM
OFF
USB
8
209

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uhk-430

Table of Contents