Appendix
Parameter name
LOCAL_LOG_LEVEL
December 2018
Installing and Administering Avaya J100 Series IP Phones
Comments on this document? infodev@avaya.com
Default
Description
value
parameter (PHNLAC) should also
be configured.
Note:
This parameter is supported
when the phone is failed over.
3
Specifies the severity levels of
events logged in the
endptRecentLog,
endptResetLog, and
endptStartupLog objects in the
SNMP MIB. Events with the
selected severity level and above
are logged.
Lower numeric severity values
correspond to higher severity levels
Value Operation:
• 0: Emergency events are logged.
• 1: Alert and Emergency events
are logged.
• 2: Critical, Alert and Emergency
events are logged.
• 3: Error, Critical, Alert and
Emergency events are logged
(default).
• 4: Warning, Error, Critical, Alert
and Emergency events are
logged.
• 5: Notice, Warning, Error, Critical,
Alert and Emergency events are
logged.
• 6: Informational, Notice, Warning,
Error, Critical, Alert and
Emergency events are logged.
• 7: Debug, Informational, Notice,
Warning, Error, Critical, Alert and
Emergency events are logged
Warning:
Setting the value to 7 can
impact the performance of the
Table continues...