1578

Module 9350 Read data from the tool table

Module 9350 reads the contents of a cell in the tool table with the status M.
The value is read as an integer value.
Call:
PS
B/W/D/K <Tool number>
PS
B/W/D/K <Tool index>
≤ 0: Main entry
PS
B/W/D/K <Element number (see Module 9092)>
CM
9350
PL
B/W/D
<Element value>
PL
B/W/D
<Error number>
0: No error, element value was read
1: Module was not called in a spawn or submit job
2: File type does not exist
3: No tool table with status M
4: Line number does not exist
5: Incorrect element number
Error code:
Marker
Value
Meaning
M4203
0
Element value read
1
Error code in W1022
W1022
2
Incorrect element number
7
Line number does not exist
20
Module was not called in a spawn or submit job
36
No tool table with status M
41
Data type for the element is not supported