HEIDENHAIN iTNC 530 HSCI Technical Manual page 1886

Hide thumbs Also See for iTNC 530 HSCI:
Table of Contents

Advertisement

1886
Call:
PS
B/W/D/K <>Mode>
0: Properties of the thin client
PS
B/W/D/K <>Name>
PLC string with name of the client
PS
B/W/D/K <>Timeout [ms]>
Module rounds up to the next 100 ms limit
0: Default timeout 3000 ms
PS
B/W/D/K <>Additional parameter 1>
Mode 0: - - -
CM
9288
PL
B/W/D
<>Error code>
0: No error
1: PLC error, error code in PLC error word (see below)
>= 100: Operating-system error
PL
B/W/D
<>Status>
Mode 0:
Bit 0: 1 = Client is master
Bit 1: 1 = Client can be master
Bit 2: 1 = Client can be displayed
Error code:
Marker
Value
Meaning
M4203
0
No error
1
Faulty execution of module
W1022
1
Mode parameter is invalid
2
Timeout parameter or additional parameter parameter
is invalid
3
Parameter name is invalid
20
Call was not in a submit/spawn job
45
PLC module cancelled (operating-system error)
51
NC software does not support module
61
Function could not be executed
100
Invalid parameter
110
Focus assignment unclear, currently no master
111
Client could not be set as master
120, 121,
Disabling of focus assignment not supported
122
130
Unknown status of focus assignment
131, 132,
Interference in communication for focus assignment
133, 134
200, 201 Internal error
HEIDENHAIN Technical Manual iTNC 530 HSCI

Advertisement

Table of Contents
loading

Table of Contents