Example of
Module 9010
1850
Module 9010/9011/9012 Read in the word range
From the specified location in the word memory the iTNC reads a byte, word
or double word and returns it as an output quantity to the stack. Indexed
reading is possible by specifying a variable as designation of the memory
location.
Call:
PS
B/W/D/K <>Address of the byte to be read>
CM
9010
; READ BYTE
PL
B
<>Target address for byte that was read>
PS
B/W/D/K <>Address of the word to be read>
CM
9011
; READ WORD
PL
B
<>Target address for word that was read>
PS
B/W/D/K <>Address of the double word to be read>
CM
9012
; READ DOUBLE WORD
PL
B
<>Target address for double word that was read>
Error code:
Marker
Value
Meaning
M4203
0
Byte was read
1
Error code in W1022
W1022
3
Invalid address was programmed
5
Module 9011: Specified address is not a word address
Module 9012: Specified address is not a double word
address
Initial state:
Byte
B10
= 35 (address)
Byte
B35
= 80 (byte to be read)
Byte
B100 = ?
Function
STL
Save the address
PS B10
(B10) of the byte to
be read from the
word accumulator in
the data stack
Read byte B35 and
CM 9010
save in the data
stack
Save data stack in
PL B100
byte B100.
Accumulator
content (dec)
35
80
HEIDENHAIN Technical Manual iTNC 530 HSCI
Data stack (dec)
35
80
80