Electronic ID label

July 2013
HEIDENHAIN inverter components of type D, as well as HEIDENHAIN
synchronous motors with absolute encoders with EnDat interface, are
equipped with an electronic ID label.
The product name, the ID number and the serial number are saved in this ID
label. These devices are automatically detected when the control is started.
Load the displayed component to the corresponding machine parameter
automatically with the SELECT soft key.
During every further control restart, the control checks whether the connected
units with electronic ID label match the entries in MP2100.x or MP2200.x. If
not, an error message might appear and the connected encoder must be
transferred to the corresponding machine parameters by soft key.
In exceptional cases, the evaluation of the electronic ID label can be
deactivated with MP7690.
MP7690
Evaluation of the electronic ID labels
Input:
%xx
Bit 0 – HEIDENHAIN power modules
0: Active
1: Inactive
Bit 1 – HEIDENHAIN synchronous motors
0: Active
1: Inactive