Module 9261 Send events
With this module you can send events to a spawn or submit job and then
interrogate them with Module 9260. You can call the module in the cyclic
program section, in submit jobs and in spawn processes. The iTNC addresses
the receiver through the identifier that the spawn command has returned. The
submit queue is addressed through the identifier $80000000 (not through the
identifier returned by the SUBM command!). The iTNC always assigns the
events that you send to the submit queue to the job that is running at the time
of arrival. If they are not read by this job, they remain for the next one. If you
wish the receiver process to start immediately, after Module 9261 you must
also call Module 9262 to enable a change of context.
Event bits 16 to 31 are reserved for the operating system (see Module 9260).
Call:
PS
D/K
<>Identifier>
Identifier from the spawn command of the receiver
K$80000000 = submit queue
PS
B/W/D/K <>Events>
Events to be triggered, bit encoded
CM
9261
Error code:
Marker
Value
Meaning
M4203
0
Event has been sent
1
Error code in W1022
W1022
30
Incorrect identifier