Proceed as follows to connect the IPC 6341 with an MC:
Connect the two Ethernet connections X116 of the IPC and the MC with
each other.
Start up both main computers, IPC and MC.
Switch to the network settings on the control via the MOD key and the code
number NET123.
Select the "eth1/X116" interface on the MC.
Press the Configuration button to switch to the settings options.
Press Load to select the existing configuration MachineNet.
Close the Settings with OK.
Activate the eth1/X11 interface.
Close the Network Settings with Apply. When you have done this, you must
restart the control to activate the changes.
11.2 IPC 6341—Industrial PC with Windows 7