When the control has restarted, open the Remote Desktop Manager
(software option 133) via the taskbar on the bottom of the screen.
Press the Add Connection button and select the connection type RDP.
In Connection Name, enter a name for the connection (e.g. Win7).
In Computer, enter the IP address of the IPC 6341 (198.168.254.3) and in
Password, enter the password for the VNC server (123).
HEIDENHAIN recommends entering a new password when commissioning
has been completed successfully.
Close the dialog with OK. The new connection is now shown in the Remote
Desktop Manager.
Select the connection.
Press the right mouse key to open a menu in which you can establish the
connection to the IPC: Start Connection.
When the connection has been established, a short message will be
displayed on the screen.
HEIDENHAIN Technical Manual iTNC 530 HSCI