Output Selected File; Load Selected File - HEIDENHAIN iTNC 530 HSCI Technical Manual

Hide thumbs Also See for iTNC 530 HSCI:
Table of Contents

Advertisement

Output
selected file

Load selected file

July 2013
The EXT1 operating mode is set with software handshake.
The iTNC outputs all of the program lines in order.
The peripheral device can:
Stop transmission with <DC3>
Resume transmission with <DC1>
iTNC to peripheral
<NUL> <NUL> <NUL>...
1st line of file <CR> <LF>...
5th line of file <CR> <LF>
6th line of file <CR> <LF>...
Last line of file <CR> <LF>
The EXT1 operating mode is set with software handshake.
To transfer a file from a peripheral device:
Enter the file name in the iTNC.
The iTNC can:
Stop transmission with <DC3>
Resume transmission with <DC1>
iTNC to peripheral
100.H "START"
<DC1>
<EOT>
If the file name in the first line and the name indicated in the iTNC are not
identical, the iTNC reads each block in and searches for the correct file name.
If the END PGM block has been read in, and the selected name is not known,
the iTNC remains static without an error message:
In this case, terminate transfer with the END key.
10.8 Data Transmission Protocols
Peripheral to iTNC
Transmission stop: <DC3>
Resume transmission: <DC1>
...
Peripheral to iTNC
<NUL><NUL>
1st line PGM100<CR><LF>
...
Last line PGM 100 <CR><LF><ETX>
1909