1830
Module 9073 Copy a string into a byte block
Module 9073 copies a string into a byte block. The module does not check
whether the string consists of valid ASCII characters. The module always
copies over the entire programmed length of the byte block, regardless of any
end-of-string identifier in the byte block.
Call:
PS
B/W/D/K <>Target byte>
PS
B/W/D/K <>Length of the byte block>
PS
B/W/D/K <>String number>
CM
9073
Error code:
Marker
Value
Meaning
M4203
0
String was copied into byte block
1
Error code in W1022
W1022
1
Invalid target byte
2
Invalid length of the programmed byte block (max. 127
characters)
4
Invalid sum of target byte and length of the byte block
11
Invalid string