6 How to Program the Low Harmonic Drive

6.3.7 5-** Digital In / Out

Par.
Parameter description
No. #
5-0* Digital I/O mode
5-00
Digital I/O Mode
5-01
Terminal 27 Mode
5-02
Terminal 29 Mode
5-1* Digital Inputs
5-10
Terminal 18 Digital Input
5-11
Terminal 19 Digital Input
5-12
Terminal 27 Digital Input
5-13
Terminal 29 Digital Input
5-14
Terminal 32 Digital Input
5-15
Terminal 33 Digital Input
5-16
Terminal X30/2 Digital Input
5-17
Terminal X30/3 Digital Input
5-18
Terminal X30/4 Digital Input
5-3* Digital Outputs
5-30
Terminal 27 Digital Output
5-31
Terminal 29 digital Output
5-32
Term X30/6 Digi Out (MCB 101)
5-33
Term X30/7 Digi Out (MCB 101)
6
5-4* Relays
5-40
Function Relay
5-41
On Delay, Relay
5-42
Off Delay, Relay
5-5* Pulse Input
5-50
Term. 29 Low Frequency
5-51
Term. 29 High Frequency
5-52
Term. 29 Low Ref./Feedb. Value
5-53
Term. 29 High Ref./Feedb. Value
5-54
Pulse Filter Time Constant #29
5-55
Term. 33 Low Frequency
5-56
Term. 33 High Frequency
5-57
Term. 33 Low Ref./Feedb. Value
5-58
Term. 33 High Ref./Feedb. Value
5-59
Pulse Filter Time Constant #33
5-6* Pulse Output
5-60
Terminal 27 Pulse Output Variable
5-62
Pulse Output Max Freq #27
5-63
Terminal 29 Pulse Output Variable
5-65
Pulse Output Max Freq #29
5-66
Terminal X30/6 Pulse Output Variable
5-68
Pulse Output Max Freq #X30/6
5-9* Bus Controlled
5-90
Digital & Relay Bus Control
5-93
Pulse Out #27 Bus Control
5-94
Pulse Out #27 Timeout Preset
5-95
Pulse Out #29 Bus Control
5-96
Pulse Out #29 Timeout Preset
5-97
Pulse Out #X30/6 Bus Control
5-98
Pulse Out #X30/6 Timeout Preset
6-48
Default value
(SR = Size related)
[0] PNP - Active at 24 V
[0] Input
[0] Input
[8] Start
[0] No operation
null
[14] Jog
[0] No operation
[0] No operation
[0] No operation
[0] No operation
[0] No operation
[0] No operation
[0] No operation
[0] No operation
[0] No operation
null
0.01 s
0.01 s
100 Hz
100 Hz
0.000 N/A
100.000 N/A
100 ms
100 Hz
100 Hz
0.000 N/A
100.000 N/A
100 ms
[0] No operation
5000 Hz
[0] No operation
5000 Hz
[0] No operation
5000 Hz
0 N/A
0.00 %
0.00 %
0.00 %
0.00 %
0.00 %
0.00 %
®
MG.16.A1.22 - VLT
is a registered Danfoss trademark
VLT HVAC Low Harmonic Drive Instruction
4 set-up
Change dur-
Conver-
ing operation
sion index
All set-ups
FALSE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-2
All set-ups
TRUE
-2
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
FALSE
-3
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
-3
All set-ups
TRUE
-3
All set-ups
FALSE
-3
All set-ups
TRUE
-
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
-2
1 set-up
TRUE
-2
All set-ups
TRUE
-2
1 set-up
TRUE
-2
All set-ups
TRUE
-2
1 set-up
TRUE
-2
Manual
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
Uint32
Uint32
Int32
Int32
Uint16
Uint32
Uint32
Int32
Int32
Uint16
Uint8
Uint32
Uint8
Uint32
Uint8
Uint32
Uint32
N2
Uint16
N2
Uint16
N2
Uint16